更(gēng)新時間:2021-09-22 點擊(jī)次(cì)數:1832次(cì)1, 電(diàn)刷: 應根(gēn)據(jù)移(yí)動用電設備使(shǐ)用(yòng)情(qíng)況每1—3個月檢查(chá)一(yī)次(cì)。重(zhòng)點(diǎn)檢(jiǎn)查集電器電刷(shuā)的磨(mó)損情況(kuàng),若磨損(sǔn)量≥5mm時(shí),必(bì)須更換(huàn)。檢查(chá)時(shí)若(ruò)發(fā)現電刷(shuā)鬆動或發(fā)生(shēng)磨(mó)損(sǔn)偏斜時,應查明原因(yīn),及(jí)時處理。
1, brush: electric equipment should be based on the use of every 1 to 3 months to check the time. Focus on examination of the collector brush wear, if wear amount is greater than or equal to 5mm, must be replaced. If found loose or wear occurs when the oblique brush check, should identify the reasons, timely treatment.
2, 集電器(qì):至少每季(jì)度(dù)檢查(chá)一(yī)次。重點檢查緊固件有(yǒu)無(wú)鬆(sōng)動,移(yí)位及塑料(liào)件和(hé)活動(dòng)件磨損情(qíng)況,檢查(chá)彈簧拉力(lì)(集(jí)電(diàn)器電刷與導(dǎo)軌(guǐ)的接觸壓力應保持一(yī)定壓力(lì)(見(jiàn)下表(biǎo))。發(fā)現問(wèn)題及時(shí)處理(lǐ)。
2, the collector: at least quarterly check once a. Focus on examination of the fastener looseness, displacement and plastic piece and a movable parts wear, check the spring tension (contact pressure collector brush and guide should maintain certain pressure (see table below). Found problems timely treatment.
3, 連接件(jiàn):至少(shǎo)每年(nián)檢(jiǎn)查(chá)一次(cì)。重(zhòng)點檢查緊固(gù)螺栓(shuān),焊(hàn)縫及支(zhī)撐(chēng)件是否(fǒu)鬆動(dòng),鏽蝕,移位等,發(fā)現問題(tí),及(jí)時處(chǔ)理。
3, connector: at least once a year to check. Key check fastening bolts, welds and support is loose and corroded, shift, found the problem, timely treatment.
4, 日常(cháng)檢查(chá):重(zhòng)點(diǎn)檢(jiǎn)查軌(guǐ)道(dào)的平(píng)直(zhí)度有(yǒu)無明顯偏(piān)差(chà)(大(dà)於20mm),錯(cuò)位(wèi),絕緣(yuán)保護件有無(wú)脫落(là),斷(duàn)裂,破損,不鏽(xiù)鋼“v"型(xíng)槽有無翹(qiáo)起;軌道(dào)上有無異物及導(dǎo)電粉塵等(děng)。必(bì)要時應(yīng)檢(jiǎn)測其絕緣(yuán)電阻是(shì)否(fǒu)符合(hé)要求(qiú)(相間絕緣(yuán)電阻(zǔ)應(yīng)≥5MΩ)。
4, the daily check: focus on examination of rail straightness has no significant deviation (more than 20mm), dislocation, insulation protection parts are loose, broken or damaged, stainless steel "V" type groove is no tilt; orbit is free of foreign matter and conductive dust etc.. When necessary, to detect the insulation resistance is to meet the requirements (interphase insulation resistance should be greater than or equal to 5M.).